8
environment. The patented Radiello® passive sampler uses a
radial design with a 360o-degree surface area to provide higher
sampling rates
than those found
with badge-style
passive samplers.
With this the
Radiello tube-style passive
sampler, Radiello
users can
achieve sam-
3. Ultra Passive Sampler for VOCs (sorbent transfers pling rates that
to tube for thermal desorption) are similar to flow
rates achieved
with sample pumps. The patented SKC Ultra® passive sampler
uses another a different approach to achieve low detection limits.
The badge-style sampler contains an internal funnel that allows sorbent to be transferred by the laboratory into a highly sensitive thermal desorption unit followed by gas chromatography . (See see
Figure 3). Sub-ppb level detection is possible for many VOCs when
Inquire On-line at www.INDUSTRIALHYGIENENEWS.com
Static Conductive Vacuums
Introducing a new line of static conductive vacuums that
are designed to eliminate nuisance
static shocks. A powerful pneumatic
vacuum that eliminates static electricity by incorporating static conductive components to suppress static
charges. Models ar eavailable in 15,
30 and 55 gallon capacities. These
vacuums are powered by compressed air. —Nortech Corporation, Div of Guardair Corp.,
800/482-7324
using thermal desorption to analyze the sample. Ultra Passive
Samplers have shown excellent correlation with canisters in side-by-side studies.
Data Interpretation
Data interpretation in the indoor environment is difficult as low- level
VOCs can be present from a variety of sources. To assist environ
mental health and safety professionals in assessing chemical levels
in indoor air, ASTM has included in the E 2600 standard typical
background concentrations of select VOCs in residences. ASTM
has also included a web links to federal and state vapor intrusion
guidance documents. As of 2007, twenty-six states had published
some form of vapor intrusion guidance including screening and
action levels for various chemicals.
Submitted by: Deborah F. Dietrich, CIH
Vice President and Corporate IH for SKC Inc.
She can be reached at 800/752-8472
Circle 27 on Card
Fan Sound Enclosure
A test reveals that the fan
sound enclosure equipment
reduces sound pressure levels
generated by fans powering
pneumatic conveying systems
from 84 dBA without the
enclosure to 64 dBA. The test
documents the enclosure supports compliance with the
OSHA Noise Standard 29 CFR
1910.95 specifications for permissible sound exposure. — Precision AirConvey,
302/999-8000
Circle 28 on Card
Circle 25 on Card
Every day, throughout the world,
we protect people’s lives. Trust us.
Portable UV
Lamp
The DeGERM-inator™ UV-
5D portable ultraviolet
sanitizer uses short-wave
UV(germicidal) light to
destroy or render harmless a wide range of disease-causing bacteria and viruses.
Simply shine the UV light over any smooth, nonporous surface to be disinfected at a distance of one-half inch ( 1. 3
cm) or less for six to eight seconds. The DeGERM-intor™
provides four to six hours of use on four AA alkaline batteries or unlimited use when powered by the AC adapter
(included). — Spectronics Corporation, 516/333-4840
Circle 29 on Card
Mouse Snap Trap
Available is a smaller version
of T-Rex rat snap trap, the
Mini-Rex. Designed with better trigger sensitivity and
more powerful trap velocity, Mini-Rex also features
patented interlocking teeth that capture mice with
unmatched holding power. Besides strength, Mini-Rex
offers PMPs ease-of-use on the job. It sets in one easy
motion. The same motions provides no-touch disposal of
the dead mouse. — Bell Laboratories, 608/241-0202
Circle 30 on Card
Year in, year out in hazardous environments around the world, lives depend on the reliable operation of
personal and fixed gas detection equipment.
Photoionization Detector
The UltraRae 3000 photoionization detector
makes use of proprietary pre-filter tubes to measure specific gases such as benzene and butadiene. The UltraRAE 3000 is wirelessly enabled and
compatible with the manufacturer’s network for
remote data measurement.The UltraRAE 3000
uses the same high-performance detection
technology as the ppbRAE 3000, with the ability
to measure toxic compounds beow 50 parts per
billion (ppb). — RAE Systems Inc., 877-723-2878
Circle 31 on Card
www.citytech.com
Circle 26 on Card
Fume Hood
The PURAIR 5 Ductless Fume Hood units
exceeds OSHA, ANSI and all relevant
international standards. The ductless
design allows the unit to be positioned
over a sink or benchtop apparatus.
There are three models available with a
choice of 24”, 36” or 48’ widths. A face velocity of 100 fpm
ensures containment of fumes and particulates for operator protection. An alarm alerts the operator when the airflow falls to an unacceptable level. All mechanisms in the
head section are on the clean side of the filter, with the
switches and electrical components being isolated from
any contamination. The main filter can be chosen from 14
different types of carbon. HEPA filters for particulate filtration are also available to suit your application. —
Air Science USA, 239/489-0024
Circle 32 on Card